Control and power cables - Shielded and armoured
2.2.1 BO-POWER N2XH 0,6/1KV (CU/XLPE/HFFR/HFFR)
0.6/1 kV XLPE insulated, halogen-free, flame retardant, single and multi-core power cables are used in inte ligent or semi-inte ligent buildings which has high dense human population like hospitals, cinemas, theatres, schools, shopping centers.
Read more 2.2.2 BO-POWER N2XH-K 0,6/1KV (CU FLEX/XLPE/HFFR/HFFR)
0.6/1 kV XLPE insulated, halogen-free, flame retardant, single and multi-core power cables are used in inte ligent or semi-inte ligent buildings which has high dense human population like hospitals, cinemas, theatres, schools, shopping centers.
Read more 2.2.3 BO-POWER N2XY 0,6/1KV (CU/XLPE/PVC/PVC)
0.6/1 kV XLPE insulated, single or multi-core power cables are used indoors and outdoors where mechanical stresses are not high, underground applications and in cable ducts, for high operating temperature (90°C). There are resistant to sudden and short-term operating temperature increases.
Read more 2.2.4 BO-POWER N2XY-K 0,6/1KV (CU/XLPE/PVC/PVC)
0.6/1 kV XLPE insulated, single or multi-core power cables are used indoors and outdoors where mechanical stresses are not high, underground applications and in cable ducts, for high operating temperature (90°C). There are resistant to sudden and short-term operating temperature increases.
Read more 2.2.5 BO-POWER NYRY 0,6/1KV (CU/PVC/PVC/SWA/PVC)
0.6/1 kV, galvanized steel wire armored, single or multi-core power cables are used in genera ly underground where high tensile stresses and mechanical protection are needed during the operation. These are resistant to increasing operating temperature in the short term.
Read more 2.2.6 BO-POWER NYCY 0,6/1KV (CU/PVC/PVC/CWCT/PVC)
0.6/1 kV power cables with copper concentric conductors and tape are used in outdoor and underground applications. The concentric conductor can be used as neutral, protective or earth and connection monitoring the impacts on the cable through a control switch or a relay.
Read more 2.2.7 BO-POWER NYBY 0,6/1KV (CU/PVC/PVC/GSTA/PVC)
0.6/1 kV, galvanized steel tape armoured power cables are used in genera ly underground where high tensile stresses and mechanical protection are needed during the operation. These are resistant to increasing operating temperature in the short term.
Read more 2.2.8 BO-POWER N2XRY 0,6/1KV (BS 5467) (CU/XLPE/PVC/SWA/PVC)
0.6/1 kV XLPE insulated, single or multi-core galvanized steel wire armoured power cables are used in genera ly underground where high tensile stresses and mechanical protection are needed during the operation. These are resistant to increasing operating temperature in the short term.
Read more 2.2.9 BO-POWER N2XRY 0,6/1KV (BS 5467) (CU/XLPE/PVC/SWA/PVC) (Copy)
0.6/1 kV XLPE insulated, halogen-free, flame retardant, single or multi-core galvanized steel wire armoured power cables are used in genera ly underground where high tensile stresses and mechanical protection are needed during the operation. These are resistant to increasing operating temperature in the short term. These cables are used in inte ligent or semi-inte ligent buildings which has high dense human population like hospitals, cinemas, theatres, schools, shopping centers.
Read more 2.2.10 BO-POWER N2XCY 0,6/1KV (CU/PVC/PVC/CWCT/PVC)
0.6/1 kV XLPE insulated, power cables with copper concentric conductors and tape are used in outdoor and underground applications. The concentric conductor can be used as neutral, protective or earth and connection monitoring the impacts on the cable through a control switch or a relay.
Read more 2.2.11 BO-POWER N2XCH 0,6/1KV (CU/XLPE/HFFR/CWCT/HFFR)
0.6/1 kV XLPE insulated, halogen-free, flame retardant, power cables with copper concentric conductors and tape are used in outdoor and underground applications. The concentric conductor can be used as neutral, protective or earth and connection monitoring the impacts on the cable through a control switch or a relay. These cables are used in inte ligent or semi-inte ligent buildings which has high dense human population like hospitals, cinemas, theatres, schools, shopping centers.
Read more 2.2.12 BO-POWER N2XBH0,6/1KV (CU/XLPE/HFFR/GSTA/HFFR)
0.6/1 kV XLPE insulated, halogen-free, flame retardant, galvanized steel tape armoured power cables are used in genera ly underground where high tensile stresses and mechanical protection are needed during the operation. These cables are used in inte ligent or semi-inte ligent buildings which has high dense human population like hospitals, cinemas, theatres, schools, shopping centers.
Read more 2.2.13 BO-POWER N2XBY 0,6/1KV (CU/XLPE/PVC/GSTA/PVC)
0.6/1 kV XLPE insulated, galvanized steel tape armoured power cables are used in genera ly underground where high tensile stresses and mechanical protection are needed during the operation. These are resistant to increasing operating temperature in the short term.
Read more 2.2.14 BO-POWER FIRE N2XCY FE180 0,6/1KV (CU+MICA/XLPE/HFFR/HFFR)
0.6/1 kV FireKab halogen-free, fire-resistant and flame retardant, single or multi-core power cables are used in inte ligent or semi-inte ligent buildings which has high dense human population like hospitals, cinemas, theatres, schools, shopping centers.
Read more 2.2.15 BO-POWER WTR49 -40°C to +90°C
BOTEC OFFSHORE POWER CABLE WTR49 CU/XLPE/LSZH/SWA/LSZH